Ultrapure water equipment is a water treatment system that employs methods such as pretreatment, reverse osmosis technology, ultrapurification treatment, and post-treatment to almost completely remove conductive media from water, as well as reduce non-dissociable colloidal substances, gases, and organic matter to very low levels.
Working Principle
1. Water enters the purification system, with the main portion flowing into the resin/membrane interior, while another portion flows along the outer side of the template to wash away ions that permeate out of the membrane.
2. The resin traps dissolved ions in the water.
3. Under the action of electrodes, the trapped ions move with anions heading toward the positive electrode and cations toward the negative electrode.
4. Cations permeate through the cation membrane and are discharged outside the resin/membrane.
5. Anions permeate through the anion membrane and are discharged outside the resin/membrane.
6. Concentrated ions are discharged from the wastewater flow path.
7. Deionized water flows out from within the resin/membrane.
Technical Requirements
1. Two-stage reverse osmosis for deep desalination, with raw water quality <2000μs and hardness <450ppm;
2. Reverse osmosis purified water meets the GB6682-2008 Grade 3 water standard, while ultrapure water exceeds the GB6682-2008 Grade 1 water standard.
3. System desalination rate ≥99.5%, with a raw water to wastewater ratio of 1:3.
4. Features self-diagnosis for abnormal operation (water quality and volume of raw water, pre-purified water, and ultrapure water), with warnings or automatic system shutdown.
5. Intelligent fault detection (online replacement indicators for key system components: solenoid valves, booster pumps, UV lamps, sensors, etc.).
RUPF SeriesUltrapure Water SystemPerformance Features
Automatic backflush function upon startup
Low-pressure alarm shutdown protection, automatic water production stop when the tank is full
Simultaneous online monitoring of 2 water quality channels, real-time monitoring of purified and ultrapure water quality
No-water alarm, full-water alarm, ensuring safety
Fully automatic RO membrane anti-scaling rinse program, extending RO membrane lifespan, automatic backflush at startup, automatic rinse during standby when water is full
Dual-quality water output, one machine for two uses (can simultaneously draw 2 streams of purified water)
Multiple specifications of water storage tanks available to meet different needs
Chassis designed with ergonomics, compliant with GLP standards
All pipelines are NSF certified, featuring new quick-connect fittings for easier filter column replacement and maintenance
Original imported nuclear-grade resin, fully descending flow ultrapurification column design, ensuring top water quality at all times
Online monitoring of water path temperature
Dual-wavelength (185nm&254nm) imported UV lamp, effective sterilization, TOC reduction, and enhanced system applicability
Original imported 0.45μm PES polyethersulfone composite terminal sterilizing filter membrane, ensuring sterile water quality
Ultrapure water constant pressure system
Automatic startup after water use with enhanced pretreatment
Name | Basic Type | Pyrogen Removal Type | Low Organic Matter Type | Comprehensive Type | |
Product Model Standard Type | RUPF | RUPF-1 | RUPF-II | RUPF-III | |
Inlet Water Requirements | Municipal tap water: TDS<200 ppm, 5-45℃, 1.0-4.0Kgf/cm2(When inlet TDS>200ppm, external softener is recommended) | ||||
System Process | PF+RO+AC+PF+ | PF+AC+PF+RO+ | PF+AC+PF+RO+ | PF+AC+PF+RO+ | |
UP Ultra Pure Water Indicators | Resistivity | 18.25MΩ.cm@25℃ | |||
Heavy Metal Ions | < 0.1 ppb | ||||
Total Organic Carbon (TOC) | <10 ppb | <3 ppb | |||
Bacteria | <0.1 cfu/ml | ||||
Pyrogen (Endotoxin) | N/A | <0.001 Eu/ml | N/A | <0.001 Eu/ml | |
Particulates (>0.2μm) | <1/ml | ||||
Ribonucleases (RNases) | N/A | <0.01 ng/ml | N/A | <0.01 ng/ml | |
Deoxyribonucleases (DNases) | N/A | <4 pg/μl | N/A | <4 pg/μl | |
Pure Water Reverse Osmosis Water Indicators | Ion Rejection Rate | 96%-99% (1. When using new RO membrane 2. Removal rate ≥99% for dual-stage reverse osmosis RO output 5μs/cm) | |||
Organic Matter Rejection Rate | >99%, when MW>200 | ||||
Particulate and Bacterial Rejection Rate | >99% | ||||
Water Production (25℃) | RUP***-10 output: 10L/H; RUP***-20 output: 20L/H; RUP***-30 output: 30L/H; RUP***-40 output: 40L/H | ||||
Instantaneous Output | 2.0 liters/minute (requires pressure water tank), (output may decrease with UF models) | ||||
Control System | Operation Mode Display | Power, water shortage, full water, purified water drawing, ultrapure water drawing, rinsing, etc.; | |||
Safety Performance | No water or low water pressure, full water shutdown, etc.; | ||||
System Monitoring | Ultrapure water quality monitoring, RO water quality monitoring, water temperature monitoring; | ||||
Water Outlets (Touch Buttons) | 2: Purified Water, UP Ultrapure Water | ||||
Dimensions/Weight | Length × Width × Height: 50×45×50cm/approx. 35Kg | ||||
Power Supply/Power | 220V, 50Hz/30W, 35W, 75W, 80W | ||||
Standard Configuration | Main unit (includes 1 purification column set) + 15L pressure water tank + accessory pack | ||||
| Industry Category | Environment |
|---|---|
| Product Category | |
| Brand: | 山东新瑞 |
| Spec: | RUPF |
| Stock: | 1000 |
| Manufacturer: | |
| Origin: | China / Shandong / Zaozhuangshi |